CRYOTON anounces a new sets of a
single-channel- and multichannel dc-SQUID-electronic, based on the FLL-channels
of the Series E115. Here we present the basic models of the dc-SQUID-electronics ( including the Control Units) for a different dc-SQUID-based systems.
dc-SQUID-based Equipment
Model SE501-L Single channel dc-SQUID electronics for LTS dc-SQUIDs
|
Model E115-L FLL-unit |
1 |
|
Model CU301-L Universal 1-channel Control Unit |
1 |
|
Software for system control |
1 |
|
Associated cables |
1 set |
Model SE501-DB Single channel dc-SQUID electronics for LTS and HTS dc-SQUIDs
|
Model E115-DB FLL-unit |
1 |
|
Model CU301-L Universal 1-channel Control Unit |
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 set |
Model SE504-L Four channel dc-SQUID electronics for LTS dc-SQUIDs
|
Model E1104-L 4-channel
FLL-unit |
1 |
|
Model CU304-L Universal 4-channel Control Unit |
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 set |
Model SE504-DB Four channel dc-SQUID electronics for LTS and HTS dc-SQUIDs
|
Model E1104-DB 4-channel FLL-unit |
1 |
|
Model CU304-L Universal 4-channel Control Unit |
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 set |
Model SE512-L Twelve channel dc-SQUID electronics for LTS dc-SQUIDs
|
Model E1112-L 12-channel
FLL-unit |
1 |
|
Model CU312-L Universal 12-channel Control Unit |
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 set |
Model SE512-DB Twelve channel dc-SQUID electronics for LTS and HTS dc-SQUIDs
|
Model E1112-DB 12-channel FLL-unit |
1 |
|
Model CU312-L Universal 12-channel Control Unit |
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 set |
Model SE516-L Twelve channel dc-SQUID electronics for LTS dc-SQUIDs
|
Model E1116-L 16-channel
FLL-unit |
1 |
|
Model CU316-L Universal
16-channel Control Unit |
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 set |
Model MM-5010-L 1-channel wide purposes dc-SQUID-based
Measuring Module
|
Model CC-blue dc-SQUID sensor |
1 |
|
Model E115-L FLL-unit |
1 |
|
Model P200 flexible dc-SQUID Probe
|
1 |
|
Model CU301-L Universal 1-channel Control Unit |
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 set |
Model MM-5010-G 1-channel dc-SQUID-based
Measuring Module
|
Model P201 dc-SQUID-based Probe with fine balanced Signal Gradiometer |
1 |
|
Model E115-L FLL-unit |
1 |
|
Model CU301-L Universal 1-channel Control Unit |
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 set |
Model MM-5030 Reference Vector dc-SQUID magnetometer (Note: modulation read-out scheme is used)
|
Model P203 XYZ-probe based on three dc-SQUIDs (for system MCG-6073-G) |
1 |
|
Model CU304-L Universal 4-channel Control Unit |
1 |
|
Model E115-L FLL-unit |
1 |
|
Software for System Control
|
1 |
|
Associated cables |
1 Set |
Model MM-5040-G 1-channel Measuring System with XYZ-magnetometer
|
Model P204 measuring Probe with Signal Gradiometer and
dc SQUID-based
Vector Magnetometer (for systems MCG-6013-GM, MCG-6013-GM) |
1 |
|
Model E1104-L FLL-unit 1 |
1 |
|
Model CU304-L Universal 4-channel Control Unit 1
|
1 |
|
Software for System Control |
1 |
|
Associated cables |
1 Set |
Descriptions of Measuring Modules and complete Measuring Systems for biomagetic
applications are presented on the page
Lab-systems
The Model E115-L is a conventional, wide purpose dc-bias FLL-unit designed for use with LTS- dc-SQUIDs.
The Model E115-DB is a universal ac/dc-bias
FLL-unit
designed for both of HTS- and LTS dc-SQUIDs
The E115-L FLL-unit hase the following parameters:
| internal noise level of the preamplifier |
0.7 nV/ÖHz. |
| modulation frequency |
100 kHz (max. 400 kHz) |
number of the feedback ranges (current feedback and flux feedback)
| 2
|
| transfer function of the feedback circuit |
1 V/F0,
0.1 V/F0 |
| bandwidth of the dc-SQUID electronics |
50 kHz (max. 200 kHz) |
| dynamic range |
130 dB (max. 160 dB). |
| slew rate |
up to 500000 Fo/s
|
The FLL-units E115-DB have the following parameters:
| internal noise level of the preamplifier
|
1 nV/ÖHz.
|
| modulation frequency |
200 kHz (max. 500 kHz) |
| ac-bias frequency |
up to 250 kHz |
| number of the feedback ranges |
2 |
| transfer function of the feedback circuit |
1 V/F0,
0.1 V/F0 |
| bandwidth of the dc-SQUID electronics |
50 kHz (max. 200 kHz)
|
| dynamic range |
130 dB (max. 160 dB). |
| slew rate |
up to 100000 Fo/s
|
As usual, the FLL-units contain an analog and
a digital part. The analog part uses a conventional null detector circuit and incorporates
a magnetic flux feedback and circuits for adjustment of the SQUID parameters. The digital part
is based on the processor and makes it possible to switch the adjustment and operation
modes of measuring channels when the system is controlled from a personal computer. The use of
processors makes new electronics very flexible in terms of programming, and provides
for convenient incorporation in a big modules for constructing of multichannel systems.
We propose to the market also the multichannel
FLL-units. They are based on both models E115-L and
E115-DB of the FLL-units. 4-, 8-, 12-, 16-, 24-, and 32-channel
modules were designed especially for a new types of MCG- and
MEG- measuring systems.
|